Creping Blades
Due to the permanent technical development in tissue through the last years it has to become more and more necessary to obtain creping blades with a longer life-time and special applications. Get in touch and try the improved creping blades with tungsten carbide coating on the top.
We provide different type of Creping Blades based on various needs.
T-Series focus on better texture.TG-Series focus on better thickness.
1. Continuous length to individual specification
2. Hardened, tempered, straight adjusted
3. Individual angle on customer requirement
4. Straightness tolerance max.0.02 mm over 1000 mm
Alloy No.:
75Cr1
Description:
ZHIXIN@ FL
Hardness:
HV: 1050-1150
Tensile strength:
1600–1800 N/mm²
Length:
after your specification
Standard width in mm:
115/120/specialist
Standard thickness in mm:
1.2/specialist
Surface:
Blue polished
Design:
Flat type
Lay:
Tungsten Carbide

ZHIXIN@ FL
Alloy No.:
75Cr1
Description:
ZHIXIN@ DM
Hardness:
HV: 1050-1150
Tensile strength:
1600–1800 N/mm²
Length:
after your specification
Standard width in mm:
115/120/specialist
Standard thickness in mm:
1.2/specialist
Surface:
Blue polished
Design:
Flat type
Lay:
Tungsten Carbide

ZHIXIN@ DM
Alloy No.:
75Cr1
Description:
ZHIXIN@ T0
Hardness:
HV: 1050-1150
Tensile strength:
1600 – 1800 N/mm²
Length:
after your specification
Standard width in mm:
115/120/specialist
Standard thickness in mm:
1.2/specialist
Surface:
Blue polished
Angle degree:
bevelled from 75-95°
Lay:
Tungsten Carbide

ZHIXIN@ T
Focus on better texture of tissues
Alloy No.:
75Cr1
Description:
ZHIXIN@ T1
Hardness:
HV: 1050-1150
Tensile strength:
1600 – 1800 N/mm²
Length:
after your specification
Standard width in mm:
115/120/specialist
Standard thickness in mm:
1.2/specialist
Surface:
Blue polished
Angle degree:
bevelled from 75-95°
Lay:
Tungsten Carbide

ZHIXIN@ TG
Focus on better thickness of tissues
Alloy No.:
75Cr1
Description:
ZHIXIN@ T2
Hardness:
HV: 1050-1150
Tensile strength:
1600 – 1800 N/mm²
Length:
after your specification
Standard width in mm:
115/120/specialist
Standard thickness in mm:
1.2/specialist
Surface:
Blue polished
Angle degree:
bevelled from 75-95°
Lay:
Tungsten Carbide

ZHIXIN@ TG
Focus on better thickness of tissues
Alloy No.:
75Cr1
Description:
ZHIXIN@ TG1
Hardness:
HV: 1050-1150
Tensile strength:
1600 – 1800 N/mm²
Length:
after your specification
Standard width in mm:
115/120/specialist
Standard thickness in mm:
1.2/specialist
Surface:
Blue polished
Angle degree:
bevelled from 75-95°
Lay:
Tungsten Carbide

ZHIXIN@ TG
Focus on better thickness of tissues
Alloy No.:
75Cr1
Description:
ZHIXIN@ TG2
Hardness:
HV: 1050-1150
Tensile strength:
1600 – 1800 N/mm²
Length:
after your specification
Standard width in mm:
115/120/specialist
Standard thickness in mm:
1.2/specialist
Surface:
Blue polished
Angle degree:
bevelled from 75-95°
Lay:
Tungsten Carbide

ZHIXIN@ TG
Focus on better thickness of tissues